How to keep an indutrial gas solenoid valve works well
To keep an industrial gas solenoid valve working well and lasting a long time, focus on clean gas, correct operation, and regular maintenance.
1. Keep the Gas Clean (Most Important)
Dirty gas is the #1 killer of solenoid valves.
-
Install a gas filter/strainer upstream (usually 50–100 mesh)
-
Clean or replace the filter regularly
-
Drain condensate (water/oil) from the gas line
-
Make sure pipe scale and welding slag are removed before commissioning
👉 Clean gas = stable opening + tight shutoff
2. Use the Correct Valve
Make sure the valve matches your system:
-
Correct gas type (natural gas, LPG, biogas, etc.)
-
Correct pressure range (don’t exceed max pressure)
-
Correct voltage (AC/DC, 24V / 110V / 220V)
-
Normally Closed (NC) or Normally Open (NO) as required
-
Explosion-proof rating if used in hazardous areas
Wrong selection = overheating, slow response, or coil burnout.
3. Proper Installation
Bad installation causes many early failures.
-
Install in the direction of flow arrow
-
Mount vertically if manufacturer recommends it
-
Support the pipeline to avoid stress on the valve body
-
Keep coil away from excessive heat (>80–90°C unless rated)
-
Use proper sealing (no excess tape entering the valve)
4. Protect the Solenoid Coil
The coil is sensitive.
-
Ensure stable power supply (no voltage fluctuation)
-
Check coil temperature during operation
-
Avoid continuous energizing beyond design limits
-
Replace coils showing discoloration or burning smell
💡 A hot coil today is a failed coil tomorrow.
5. Regular Inspection & Testing
Set a simple maintenance routine:
-
Weekly/monthly:
-
Check for gas leakage
-
Listen for abnormal buzzing or delayed action
-
-
Quarterly:
-
Test open/close response time
-
Clean valve internals if allowed
-
-
Annually:
-
Replace seals, O-rings, or diaphragm (if applicable)
-
6. Prevent Frequent On–Off Cycling
Excessive switching shortens valve life.
-
Use control logic or timers to reduce rapid cycling
-
For high-frequency control, consider:
-
Proportional valve
-
Motorized valve
-
Valve rated for high cycling
-
7. Keep Environment Friendly
-
Protect from dust, moisture, and corrosive gases
-
Use IP-rated or weatherproof coils outdoors
-
Avoid vibration or shock near the valve
8. Act Fast on Early Symptoms
Replace or service the valve if you notice:
-
Slow opening or closing
-
Valve stuck open or closed
-
Gas leakage when closed
-
Coil overheating or noise
Ignoring small problems often leads to safety shutdowns or burner trips.
Quick Summary
✅ Clean gas
✅ Correct selection
✅ Proper installation
✅ Stable power
✅ Regular inspection
✅ Avoid excessive cycling